SCANMODE=PERIODIC, SCANCONF=DIRMAP, DMAWU=DISABLE, DEBUGRUN=X0
Configuration Register
| SCANMODE | Configure scan mode 0 (PERIODIC): A new scan is started each time the period counter overflows 1 (ONESHOT): A single scan is performed when START in CMD is set 2 (PRS): Pulse on PRS channel |
| SCANCONF | Select scan configuration 0 (DIRMAP): The channel configuration register registers used are directly mapped to the channel number. 1 (INVMAP): The channel configuration register registers used are CH 2 (TOGGLE): The channel configuration register registers used toggles between CH 3 (DECDEF): The decoder state defines the CONF registers to be used. |
| DUALSAMPLE | Enable dual sample mode |
| STRSCANRES | Enable storing of SCANRES |
| DMAWU | DMA wake-up from EM2 0 (DISABLE): No DMA wake-up from EM2 1 (ENABLE): DMA wake-up from EM2 when FIFO count is greater or equal to RESFIDL |
| RESFIDL | Result FIFO level |
| DEBUGRUN | Debug Mode Run Enable 0 (X0): LESENSE can not start new scans in debug mode 1 (X1): LESENSE can start new scans in debug mode |